You are in: Home > Products > Obsolete products
NHC-H34 - Digital Electronic Controller for Water Heaters with Solar collector
NHC-H34 is a new generation of electronic temperature regulators, designed for management and control of an electric water heaters, combined with a solar thermal collectors. Both models have a modern, multifunctional graphic LCD display. Via these temperature regulators a new class of combined electric boilers is developed, combining the electrical and solar power in one device.
Energy saving mode Smart
Among the important features of these temperature regulators are:
- Reducing the prime cost of the water heating system – one boiler with a joint regulator for the two types of power. No need of a separate controller for control of the circulating pump.
- Better integration of solar and electrical power. As you know, the solar power is generated free of charge and the electrical power is always available.
- Antibacterial protection of the water. Periodic water heater is heated to 70 degrees, thanks to which destroy bacteria penetrated by water
- A modern design and new useful information for water heater users.
Working with solar collector and electric heater
The digital controllers NHC-H33 / NHC-H34 have some specific advanced features, which can not be found in other devices of the same class:
- Power adding when the sun can not heat the water up to the necessary temperature.
- An automatic anti-freeze function, protecting the boiler from freezing by starting the electric heater when the water temperature drops below 3°C.
- An automatic anti-freeze function, protecting the solar collector system from freezing. When the temperature drops below the freezing point of the heat-transfer fluid the circulating pump will start and will transfer heat from the boiler to the solar collector.
- Overheating protection of the solar collector - If the warm water in the boiler is not used for a longer period and the heat coming from the collector can not be transferred anywhere, an alarm will be activated.
- Providing information about the status of the anode protector.
- Providing information about electric leakage from the heater to the casing more than 30mA.
- Available adaptive power-saving algorithm used in the electric heater to heat the water.
- Self-diagnostic of all circuits.
- There is an option to connect an UPS in order to keep the circulating pumps working until the mains is back.
- A clock, which allows programming of a specific scheme for switching on and off of the electric heater, ensuring an automatic use of a time zone with cheaper power.
- Delayed start timer, allowing adjusting the date and time for start up of the electric heater.
- An option for separate measuring of the consumed electrical power in kWh in two or more tariffs or graphically.
- Simultaneous display of the water temperature in the lower and upper side of the boiler and of the temperature in the heat-exchanger of the solar collector.
- Automatic protection of the solar collector from overheating during long absence from home by Holiday mode
Holiday mode is activated
NHC-H33 / NHC-H34 are designed for building in the production of new water heaters made by Eldominvest Ltd.
|